Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.599
Filtrar
1.
Transfus Clin Biol ; 30(4): 436-442, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37673392

RESUMO

OBJECTIVES: An intronic A4GALT single nucleotide variant, rs5751348:G>T, P2 or A4GALT*02 allele has a lower level of the enzyme-encoding A4GALT transcripts than the P1 individuals. Here, we first develop and validate a simple inhouse PCR-SSP method to detect A4GALT*01 and A4GALT*02 alleles, and second, apply this method to compare the allele frequencies between Thai and other populations. MATERIAL AND METHODS: The conventional test tube technique was used to detect the P1 antigen in 222 blood samples from Thai blood donors at Thammasat University Hospital. A PCR-SSP method was optimized and validated for reproducibility and specificity to identify these alleles and was subsequently tested on 1,840 DNA samples of unknown phenotypes obtained from central, northern and southern Thais. In addition, allele frequencies of central Thais were compared with those of other populations. RESULTS: In the tested cohort (n = 222), P1 and P2 phenotypes were typed in 26.13 and 73.87% of donors, respectively. The developed PCR-SSP was successfully optimized, and the outcomes were consistent with those of serological phenotyping and DNA sequencing results, demonstrating its validity for predicting P1/P2 phenotype. For central, northern and southern Thais, the A4GALT*01 frequency was 0.1579 (430/2,724), 0.1183 (71/600), and 0.2575 (206/800), whereas the A4GALT*02 frequency was 0.8421 (2,294/2,724), 0.8817 (529/600), and 0.7425 (594/800), respectively. Their observed frequencies among central Thais significantly differed from those in other populations (p < 0.05). CONCLUSION: Our study has successfully developed a simple, precise, and reliable method to genotype A4GALT*01 and A4GALT*02 using inhouse developed PCR-SSP for predicting P1/P2 status.


Assuntos
Doadores de Sangue , Tipagem e Reações Cruzadas Sanguíneas , População do Sudeste Asiático , Humanos , Alelos , Genótipo , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Tailândia , Tipagem e Reações Cruzadas Sanguíneas/métodos
2.
Transfus Med ; 33(5): 379-389, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37728214

RESUMO

BACKGROUND: Pre-transfusion testing (PTT) encompasses a set of mandatory laboratory tests performed before red blood cell transfusion. The antibody screen, one component of PTT, commonly includes a 10-20 min incubation. The primary aim of this study was to determine if this period can be reduced when using current immunohematology methodologies. METHODS AND MATERIALS: Antibody screens were performed on reagent samples using Glass or Gel-based column agglutination technologies (CAT) and a solid phase red cell adherence (SPRCA) assay, with incubation periods of 1, 5, 10 and 15 min, and 20 min (SPRCA assay only). For each method, the shortest period producing a minimum of a 1+ reaction with all reagent samples was considered optimal. The sensitivity of each assay using the optimal period was calculated after performing antibody screens on 100 patient samples. RESULTS AND DISCUSSION: It was demonstrated that the incubation period in the SPRCA and Glass CAT systems can be reduced to 5 and 10 min, respectively, while achieving high assay sensitivity (98.9% in both). The incubation period in the Gel CAT system cannot be reduced from 15 min. Significant association between titre and reaction strength was observed for all three screening methods (p < 0.001 for both CAT methods, p = 0.041 for SPRCA). This study demonstrates that the incubation period used in the antibody screen can be reduced when using systems employing the Glass CAT and SPRCA methods, without affecting assay sensitivity. If confirmed, it could result in faster completion of PTT.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas , Eritrócitos , Humanos , Tipagem e Reações Cruzadas Sanguíneas/métodos , Eritrócitos/imunologia , Fatores de Tempo , Sensibilidade e Especificidade , Anticorpos/imunologia
3.
Obstet Gynecol ; 138(5): 788-794, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34619726

RESUMO

OBJECTIVE: To evaluate patient safety, resource utilization, and transfusion-related cost after a policy change from universal type and screen to selective type and screen on admission to labor and delivery. METHODS: Between October 2017 and September 2019, we performed a single-center implementation study focusing on risk-based type and screen instead of universal type and screen. Implementation of our policy was October 2018 and compared 1 year preimplementation with 1 year postimplementation. Patients were risk-stratified in alignment with California Maternal Quality Care Collaborative recommendations. Under the new policy, the blood bank holds a blood sample for processing (hold clot) on patients at low- and medium-risk of hemorrhage. Type and screen and crossmatch are obtained on high-risk patients or with a prior positive antibody screen. We collected patient outcomes, safety and cost data, and compliance and resource utilization metrics. Cost included direct costs of transfusion-related testing in the labor and delivery unit during the study period, from a health system perspective. RESULTS: In 1 year postimplementation, there were no differences in emergency-release transfusion events (4 vs 3, P>.99). There were fewer emergency-release red blood cell (RBC) units transfused (9 vs 24, P=.002) and O-negative RBC units transfused (8 vs 18, P=.016) postimplementation compared with preimplementation. Hysterectomies (0.05% vs 0.1%, P=.44) and intensive care unit admissions (0.45% vs 0.51%, P=.43) were not different postimplementation compared with preimplementation. Postimplementation, mean monthly type and screen-related costs (ABO typing, antibody screen, and antibody workup costs) were lower, $9,753 compared with $20,676 in the preimplementation year, P<.001. CONCLUSION: Implementation of selective type and screen policy in the labor and delivery unit was associated with projected annual savings of $181,000 in an institution with 4,000 deliveries per year, without evidence of increased maternal morbidity.


Assuntos
Transfusão de Sangue/economia , Transfusão de Sangue/métodos , Trabalho de Parto , Segurança do Paciente , Adulto , Bancos de Sangue , Tipagem e Reações Cruzadas Sanguíneas/economia , Tipagem e Reações Cruzadas Sanguíneas/métodos , Custos e Análise de Custo , Feminino , Hemorragia/epidemiologia , Hospitalização/estatística & dados numéricos , Humanos , Histerectomia/estatística & dados numéricos , Unidades de Terapia Intensiva/estatística & dados numéricos , Políticas , Gravidez , Adulto Jovem
4.
Transfus Apher Sci ; 60(6): 103230, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34400096

RESUMO

BACKGROUND: Accurate ABO typing is essential for preventing ABO incompatibility reactions. However, the causes of ABO grouping discrepancy has not been sufficiently studied, and it may vary among different ethnic populations. Thus, the aim of this retrospective study was to investigate the causes of ABO discrepancy in the East Asian population. MATERIALS AND METHODS: A retrospective observational study on ABO typing discrepancy among patients in a tertiary hospital was carried out using the electronic medical record database of Samsung Medical Center (Seoul, Korea) between July 2016 and May 2019. RESULTS: ABO grouping was performed on 551,959 blood samples during the study period; 1468 events of serologic ABO discrepancy were determined from 1334 (0.24 %) samples. A total of 134 samples (0.02 %) presented multiple causes of ABO discrepancy. Weak/missing serum reactivity (594, 40.5 %) was the most frequent reason for ABO discrepancy, followed by extra serum reactivity (370, 25.2 %), weak/missing red cell reactivity (267, 18.2 %), mixed-field red cell reactivity (176, 12.0 %), and extra red cell reactivity (61, 4.2 %). In the category of weak/missing red cell reactivity, ABO subgroup was the most common reason, and using ABO genotyping, 26.2 % of the cases genotyped were found to be related to the cis-AB allele. CONCLUSIONS: Our results suggest that the incidence and cause of ABO typing discrepancies vary among institutes and ethnic groups. Our data helps to better understand and facilitate the resolution of ABO typing discrepancies in patients.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Tipagem e Reações Cruzadas Sanguíneas/métodos , Feminino , Humanos , Incidência , Masculino , República da Coreia , Estudos Retrospectivos , Centros de Atenção Terciária
5.
Transfusion ; 61(10): 2918-2924, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34268735

RESUMO

BACKGROUND: Blood donor screening includes tests using capillary blood, which is usually obtained by finger pricking using a lancet; however, the lancet has some shortcomings, such as skin puncture pain and needle stick injury. Recently, laser lancing devices for finger-prick sampling have been developed. We compared capillary blood Hb (cHb) levels and blood typing results obtained using a laser lancing device with those obtained using a lancet. STUDY DESIGN AND METHODS: cHb levels, blood typing results, and skin puncture pain scores were assessed in 191 participants. Finger-prick sampling was performed using LMT-1000 (LaMeditech, Seoul, Korea) and a lancet on the same finger on different hands. Paired venous Hb (vHb) levels were assessed in 103 participants using an automated hematology analyzer and compared with the cHb levels obtained using both lancing devices. RESULTS: The paired cHb results obtained with the laser lancing device and lancet showed a strong correlation (r = 0.927, p < .001) without any significant difference (p = .113) and a substantial agreement (κ = 0.654) for the identification of participants with a low Hb level (<12.5 g/dl). cHb levels were significantly higher than vHb levels with both lancing devices (mean differences: 0.27-0.43 g/dl). The results of blood typing using the laser lancing device showed 100% accuracy. Use of the laser lancing device showed significantly lower skin puncture pain scores (p < .001). CONCLUSION: Use of a laser lancing device for capillary Hb measurement and blood typing showed accurate results, with significantly reduced skin puncture pain. Laser lancing devices could be feasible for donor screening tests.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/instrumentação , Coleta de Amostras Sanguíneas/instrumentação , Hemoglobinometria/instrumentação , Doadores de Sangue , Tipagem e Reações Cruzadas Sanguíneas/métodos , Coleta de Amostras Sanguíneas/métodos , Feminino , Hemoglobinometria/métodos , Hemoglobinas/análise , Humanos , Lasers , Masculino
6.
Surgery ; 170(4): 1240-1247, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34092375

RESUMO

BACKGROUND: Positive crossmatch (XM+) combined liver-kidney transplantation due to preformed donor-specific human leukocyte antigen antibodies has produced mixed results. We sought to understand the role of delayed kidney transplant approach in XM+ combined liver-kidney transplantations. METHODS: XM+ combined liver-kidney transplantations were retrospectively reviewed. T- and B-cell XM, complement-dependent cytotoxic crossmatch, and flow cytometric crossmatch were performed prospectively. RESULTS: Of 183 combined liver-kidney transplantations performed (2002-2019), 114 (62%) were with "delayed" kidney transplant approach and 19 (19 of 183, 10%) were XM+. Of 19 XM+ combined liver-kidney transplantations, kidney transplant was "delayed" in 14 by an average of 47 hours (range 24-64 hours) from liver transplant. There was a significant reduction in both class I (mean pre-liver transplant mean fluorescence intensity (MFI) 26,230 versus mean post-liver transplant and pre-delayed kidney transplant MFI 3,272, P = .01) and total MFI (mean pre-liver transplant MFI 27,233 vs mean post liver transplant and predelayed kidney transplant MFI 11,469, P = .01). However, there was no significant change in the MFI of class II donor-specific antibodies (mean pre-liver transplant MFI 17,899 versus post-liver transplant and pre-delayed kidney transplant MFI 14,341, P = .19). None of XM+ delayed kidney transplants had delayed graft function, and there was no antibody-mediated rejection. One-year patient survival for the XM+ combined liver-kidney transplantation with delayed kidney transplant approach was 92.9%, which is comparable to patient survival of XM- combined liver-kidney transplantation. Whereas patient survival in recipients before "delayed" approach ("simultaneous"; n = 5) was 40% when liver-kidney transplants were performed simultaneously (P = .06). CONCLUSION: In sensitized combined liver-kidney transplantation recipients, the "delayed" kidney transplant approach is associated with a significant reduction in total and class I donor-specific antibodies after liver transplant before kidney transplant, enabling therapeutic interventions such as plasmapheresis, if needed, providing optimal outcomes similar to crossmatch recipients.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/métodos , Rejeição de Enxerto/diagnóstico , Antígenos HLA/imunologia , Teste de Histocompatibilidade/métodos , Transplante de Rim , Transplante de Fígado , Tempo para o Tratamento , Adulto , Idoso , Feminino , Rejeição de Enxerto/imunologia , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Doadores de Tecidos , Adulto Jovem
8.
Transfusion ; 61(8): 2265-2276, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34110629

RESUMO

BACKGROUND: There are limited standards guiding the selection and processing of blood components specific for neonatal and pediatric transfusions. Therefore, blood banks (BBs) and transfusion services must create their own policies and procedures. STUDY DESIGN AND METHODS: The American Association of Blood Banks (AABB) Pediatric Transfusion Medicine Subsection Committee developed a 74-question survey to capture neonatal and pediatric BB practices in the United States. RESULTS: Thirty-five centers completed the survey: a response rate 15.8%. Responses indicated that most carry a mixed inventory of red blood cells (RBCs); 94.2% allow more than one type of RBC product for small-volume (SV) and large-volume (LV) transfusions to neonatal and pediatric patients. Many had storage age thresholds for RBCs transfused to neonates (SV = 60%, LV = 67.7%) but not older pediatric patients. The use of Group O for nonurgent RBC transfusion in neonates was common (74.2%). Responses related to special processing of RBCs and platelets indicated that 100% RBC and platelets are leukocyte-reduced (LR) for neonates and 97% for non-neonates. Irradiation of RBCs and platelets was commonly performed for neonatal transfusion (88.6%). Providing cytomegalovirus (CMV) seronegative products, volume reduction, and washing were variable. All centers transfused single-donor apheresis platelets; 20% allowed pathogen reduction (PR). The majority of centers have strategies limiting the amount of incompatible plasma transfused; however, few titrate ABO isoagglutinins in plasma-containing products (20% for platelets and 9.1% for plasma). CONCLUSIONS: Variability exists in BB practice for neonatal and pediatric transfusion. Future studies are needed to understand and define best BB practices in these patient populations.


Assuntos
Transfusão de Sangue , Bancos de Sangue , Tipagem e Reações Cruzadas Sanguíneas/métodos , Preservação de Sangue/métodos , Transfusão de Sangue/métodos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Medicina Transfusional , Estados Unidos
9.
Transpl Immunol ; 67: 101418, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34052300

RESUMO

Immunocomplex capture fluorescence analysis (ICFA) which basic principle is same as Luminex crossmatch (LXM), could detect donor-specific HLA antibody (DSA). The advantages of ICFA are (i) detection of DSA and (ii) no requirement of viable cells over the flow cytometry crossmatch (FCXM). However, FCXM has been widely used because of its higher sensitivity than ICFA, in particular HLA-class II antibody detection. In this study the accuracy of DSA detection against HLA-class II was investigated by modifying the original method of ICFA. Increment of the sensitivity was found when purified peripheral blood mononuclear cells (PBMCs) were used instead of whole blood. An ICFA-PBMC in addition to FCXM-T/B was conducted for 118 patients before kidney transplantation and 13 patients with de novo DSA against HLA-class II after transplantation. Significantly positive correlation was observed between the values of ICFA-PBMC and DSA mean fluorescence intensity (MFI) targeting class II (p < 0.0001). When the cutoff level of 1.4 was determined by receiver operating characteristic curve analysis, the average DSA MFI was found to be significantly higher in the ICFA-PBMC (class II) positive group comparing to that in the negative group (12,217 vs 3885, p = 0.0027). ICFA-PBMC and optimized cutoff level could provide valid information in cases of suspected DSA.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/métodos , Rejeição de Enxerto/diagnóstico , Isoanticorpos/sangue , Transplante de Rim , Leucócitos Mononucleares/imunologia , Complexo Antígeno-Anticorpo/metabolismo , Fluorescência , Antígenos HLA/imunologia , Humanos , Isoantígenos/imunologia , Sensibilidade e Especificidade , Doadores de Tecidos
10.
Ann Clin Lab Sci ; 51(2): 267-270, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33941569

RESUMO

Managing a platelet blood product inventory in a hospital-based transfusion service (TS) is challenging. Thus, to optimize platelet inventory availability and to prevent excess outdating, most tertiary care center-based TSs do not require ABO-identical platelet (PLT) transfusions. To mitigate the risk of hemolysis associated with the transfusion of high titer ABO antibody-containing PLT, our institutional policy allows the transfusion of PLT containing ABO-incompatible plasma only if PLT is re-suspended in platelet additive solution (PAS). Despite the steps taken to reduce the risk of hemolytic transfusion reactions to PLT transfusions at our institution, our center has observed hemolytic reactions to PLT in PAS. The current case study highlights the importance of recognizing a hemolytic reaction (HTR) from ABO-incompatible PLT transfusions and discusses the current strategies and recommendations to mitigate this risk.


Assuntos
Hemólise/imunologia , Transfusão de Plaquetas/métodos , Reação Transfusional/imunologia , Sistema ABO de Grupos Sanguíneos/imunologia , Idoso , Tipagem e Reações Cruzadas Sanguíneas/métodos , Plaquetas/imunologia , Transfusão de Sangue/métodos , Feminino , Humanos , Plasma/imunologia
11.
Transfusion ; 61(7): 2054-2063, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33960433

RESUMO

BACKGROUND: Daratumumab, a human anti-CD38 monoclonal antibody used to treat multiple myeloma, interferes with pretransfusion testing and can mask alloantibodies. Incidence of alloimmunization in patients on daratumumab has not been well characterized, and optimal transfusion guidelines regarding prophylactic antigen matching, accounting for both patient safety and efficiency, have not been well established for these patients. METHODS: Records of patients who received daratumumab between January 1, 2014 and July 2, 2019 were reviewed. Daratumumab interference with pretransfusion testing was managed by testing with reagent red blood cells (RBCs) treated with 0.2 M dithiothreitol. When daratumumab was present during antibody testing, patients were transfused with RBC units prophylactically matched for D, C, c, E, e, and K antigens per hospital policy. RESULTS: Out of 90 patients identified, 52 received a total of 638 RBC transfusions (average of 12.3 units per patient, SD 17.2, range 1-105, median 5 among those transfused). Alloantibodies existing before daratumumab initiation were identified in seven patients. No new alloantibodies were detected in any patients after starting daratumumab treatment. CONCLUSIONS: The incidence of alloimmunization in patients receiving daratumumab is low. Whether this is due to the effect of daratumumab, underlying pathophysiology, or other factors, is unknown. Because these patients require a large number of RBC transfusions overall and have little observed alloimmunization, phenotype matching (beyond RhD) may be unnecessary. Since the use of dithiothreitol cannot rule out the presence of anti-K, we recommend transfusion of ABO-compatible units, prophylactically matched for the D and K antigens only.


Assuntos
Anticorpos Monoclonais/imunologia , Antineoplásicos Imunológicos/imunologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Artefatos , Incompatibilidade de Grupos Sanguíneos/sangue , Tipagem e Reações Cruzadas Sanguíneas , Transfusão de Sangue , Eritrócitos/imunologia , Isoanticorpos/sangue , Mieloma Múltiplo/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aloenxertos , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/uso terapêutico , Antineoplásicos Imunológicos/administração & dosagem , Antineoplásicos Imunológicos/uso terapêutico , Antígenos de Grupos Sanguíneos/imunologia , Incompatibilidade de Grupos Sanguíneos/diagnóstico , Incompatibilidade de Grupos Sanguíneos/epidemiologia , Tipagem e Reações Cruzadas Sanguíneas/métodos , Terapia Combinada , Ditiotreitol/farmacologia , Eritrócitos/efeitos dos fármacos , Feminino , Transplante de Células-Tronco Hematopoéticas , Humanos , Incidência , Isoanticorpos/biossíntese , Isoanticorpos/imunologia , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/tratamento farmacológico , Transplante Autólogo
13.
Arch Iran Med ; 24(2): 107-112, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33636977

RESUMO

BACKGROUND: The requests for blood products in elective surgeries exceed actual use, leading to financial wastage and loss of shelf-life. In this study, we assessed the blood transfusion indices in elective surgeries performed in the operating rooms. METHODS: In this cross-sectional study, from January to June 2017, a total of 970 adult patients who underwent elective surgeries in the operating rooms of Nemazee hospital, a general referral hospital in southern Iran, were investigated. Demographic, clinical, and laboratory data, such as hemoglobin (Hb), hematocrit (Hct), platelets, prothrombin time (PT), and partial thromboplastin time (PTT) were gathered from medical records. Blood utilization was evaluated using the following indices: cross-match to transfusion ratio (C/T ratio), transfusion probability (T%), transfusion index (TI), and Maximum Surgical Blood Order Schedule (MSBOS). RESULTS: The overall C/T, T%, and TI ratios were 2.49, 46.6%, and 0.83 for all procedures, and the highest and lowest ratios pertained to the thoracic and cardiac surgeries, respectively. The C/T ratio was ≥2.5 for all surgical procedures except for cardiac surgeries. T% was <30 for thoracic and orthopedics surgeries and ≥30 for other surgical procedures. In all surgical procedures, TI was less than 0.5, except for cardiac surgeries. Also, the MSBOS was about 3 units for cardiac surgeries and ranged from 0.5 to 1 units in other surgeries. CONCLUSION: The results of this study showed a high quality blood transfusion practice in cardiac surgeries, possibly due to more focus on this critical ward. Assessing difficulties in the process of reservation, utilization, and preparation of standard protocols and policies are required to improve the blood utilization practice in operating rooms.


Assuntos
Transfusão de Sangue/estatística & dados numéricos , Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Idoso , Tipagem e Reações Cruzadas Sanguíneas/métodos , Tipagem e Reações Cruzadas Sanguíneas/estatística & dados numéricos , Transfusão de Sangue/métodos , Estudos Transversais , Feminino , Humanos , Irã (Geográfico) , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas/organização & administração , Estudos Retrospectivos
14.
Transfusion ; 61(4): 1222-1234, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33580979

RESUMO

BACKGROUND: Patients can form antibodies to foreign human leukocyte antigen (HLA) Class I antigens after exposure to allogeneic cells. These anti-HLA class I antibodies can bind transfused platelets (PLTs) and mediate their destruction, thus leading to PLT refractoriness. Patients with PLT refractoriness need HLA-matched PLTs, which require expensive HLA typing of donors, antibody analyses of patient sera and/or crossmatching. An alternative approach is to reduce PLT HLA Class I expression using a brief incubation in citric acid on ice at low pH. METHODS AND MATERIALS: Apheresis PLT concentrates were depleted of HLA Class I complexes by 5 minutes incubation in ice-cold citric acid, at pH 3.0. Surface expression of HLA Class I complexes, CD62P, CD63, phosphatidylserine, and complement factor C3c was analyzed by flow cytometry. PLT functionality was tested by thromboelastography (TEG). RESULTS: Acid treatment reduced the expression of HLA Class I complexes by 71% and potential for C3c binding by 11.5-fold compared to untreated PLTs. Acid-treated PLTs were significantly more activated than untreated PLTs, but irrespective of this increase in steady-state activation, CD62P and CD63 were strongly upregulated on both acid-treated and untreated PLTs after stimulation with thrombin receptor agonist peptide. Acid treatment did not induce apoptosis over time. X-ray irradiation did not significantly influence the expression of HLA Class I complexes, CD62P, CD63, and TEG variables on acid treated PLTs. CONCLUSION: The relatively simple acid stripping method can be used with irradiated apheresis PLTs and may prevent transfusion-associated HLA sensitization and overcome PLT refractoriness.


Assuntos
Ácido Cítrico/efeitos adversos , Antígenos de Histocompatibilidade Classe I/efeitos dos fármacos , Transfusão de Plaquetas/métodos , Imunodeficiência Combinada Severa/induzido quimicamente , Anticorpos/imunologia , Tipagem e Reações Cruzadas Sanguíneas/métodos , Plaquetas/efeitos da radiação , Feminino , Antígenos de Histocompatibilidade Classe I/imunologia , Antígenos de Histocompatibilidade Classe I/metabolismo , Antígenos de Histocompatibilidade Classe I/efeitos da radiação , Teste de Histocompatibilidade/economia , Teste de Histocompatibilidade/métodos , Humanos , Selectina-P/metabolismo , Transfusão de Plaquetas/efeitos adversos , Plaquetoferese/métodos , Tetraspanina 30/metabolismo , Tromboelastografia/métodos , Trombocitopenia/terapia , Regulação para Cima/genética
15.
J Clin Lab Anal ; 35(3): e23695, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33543811

RESUMO

Anti-human globulin (AHG) reagents are widely applied in pretransfusion compatibility tests. The accuracy of detection with AHG reagents is mainly affected by irregular antibodies or cold agglutinins in blood samples, which are related to the human complement system. Although much has been written about various types and applications of AHG reagents, their characteristics, interference factors and optimal selection in pretransfusion compatibility tests still need to be further clarified. Here, we review clinical practice and basic studies that describe each AHG reagent, summarize the advantages and disadvantages of using different AHG reagents in the presence of cold agglutinins or complement-fixing antibodies, explore the potential mechanisms by which the complement system influences detection with AHG reagents and address the question of how to optimally select AHG reagents for clinically significant antibody detection.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/métodos , Indicadores e Reagentes , Soroglobulinas/imunologia , Aglutininas , Teste de Coombs , Humanos , Imunoglobulina G/imunologia
16.
Transfus Med ; 31(2): 129-135, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33429462

RESUMO

OBJECTIVES: This study evaluated the red blood cell (RBC) Lewis phenotypes by simple haemagglutination technique and molecular genotyping in healthy individuals. BACKGROUND: The expression of Lewis antigen on RBCs is dependent on the interaction of FUT3 and FUT2 genes. Complexity of the genetic control of Lewis antigen expression and the error-prone nature of Lewis phenotyping result in non-genuine RBC Lewis phenotypes, which could be misleading. MATERIALS AND METHODS: ABO blood group and RBC Lewis phenotypes were determined by conventional haemagglutination tube techniques. FUT2 and FUT3 genotypes were analysed by polymerase chain reaction and direct DNA sequencing. The RBC Lewis phenotypes were also inferred from the FUT2 and FUT3 genotyping results. RESULTS: The frequencies of RBC Lewis phenotypes typed by the conventional tube test were Le(a+b-) 19.63%, Le(a-b+) 49.32% and Le(a-b-) 31.05%, whereas the frequencies inferred from the FUT2 and FUT3 genotypes were Le(a+b-) 20.09%, Le(a-b+), 59.82%; Le(a-b-), 17.81%; and Le(a+b+), 5 (2.28%). The Le(a+b+) phenotype was not detected by the tube test, and a significant difference was observed in the frequencies of the determined Le(a-b-) and Le(a-b+) phenotypes. CONCLUSION: The phenotyping and genotyping of Lewis blood group system reveal a high rate of discordance in the frequencies of Lewis phenotypes among the healthy individuals.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/métodos , Eritrócitos/imunologia , Fucosiltransferases/genética , Técnicas de Genotipagem/métodos , Antígenos do Grupo Sanguíneo de Lewis/genética , Fenótipo , Adolescente , Adulto , Idoso , Feminino , Marcadores Genéticos , Genótipo , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Análise de Sequência de DNA , Adulto Jovem
17.
J Immunol Methods ; 492: 112968, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33465386

RESUMO

BACKGROUND: The monocyte monolayer assay (MMA) is an in-vitro assay that can predict the outcome of blood transfusion of antigen positive units when serologically compatible blood is not available. MATERIALS AND METHODS: Fifty-four patients testing positive by the antibody screening test using gel agglutination were further examined by the alloantibody identification panel to determine alloantibody specificity. After determining and categorizing the antibodies, patients' samples were examined using the MMA to determine the clinical significance of the detected alloantibodies. We also tested 2 seeding methods (24-well cell culture plates versus 8-well chamber-slides) and 3 visualization/staining techniques (unstained phase contrast, Leishman and Giemsa staining). RESULTS: 35 out of the 54 cases (64.8%) had a monocyte index of >5% which is predictive of occurrence of hemolytic reaction after transfusion; 23 cases with antibodies known to be clinically significant [anti-C, anti-E, anti-c, anti-K, anti-Fy(a), anti Fy(b), anti-JK(b)], 2 with Anti-M specificity, 7 cases with autoantibodies and 3 cases with multiple antibodies. On the other hand, 19 out of the 54 (35.2%) cases included in the study showed a monocyte index of <5% which is predictive of absence of hemolytic reaction after transfusion. The 8-well chamber-slides were better than the 24-well culture plates, as the latter showed a lot of un-phagocytosed RBCs in the background. Also, Leishman staining was better than Giemsa staining with better and clearer differentiation between the RBCs, monocytes and phagocytic vacuoles. CONCLUSION: MMA can be used as a surrogate cross-match test for the selection of blood units in cases where antigen-negative blood units are not available.


Assuntos
Antígenos de Grupos Sanguíneos/imunologia , Tipagem e Reações Cruzadas Sanguíneas/métodos , Isoanticorpos/análise , Monócitos/imunologia , Reação Transfusional/prevenção & controle , Técnicas de Cultura de Células , Humanos , Isoanticorpos/imunologia
18.
Hum Immunol ; 82(3): 147-154, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33478842

RESUMO

The ability to identify specific HLA molecules against which a patient has alloantibodies has revolutionized assessment of immunologic compatibility. Anti-HLA antibodies are typically evaluated as reactive against well-defined serologic antigen groups. Thus, donor HLA genotyping is aimed at defining HLA at the serologic split-antigen level to avoid incompatible antigen-antibody combinations. However, anti-HLA antibodies can have reactivities not accurately described by well-defined serologic antigens. While existence of these antibodies is acknowledged, their precise impact on clinical practice is not clear. We performed a single-center review of 2 years of pre-and post-transplant anti-HLA antibody testing data combined with high-resolution HLA genotyping data for living and deceased organ donors to evaluate the clinical impact of anti-HLA antibodies with reactivities outside of commonly defined serologic antigen groups. We find approximately 15% of patients awaiting transplantation have alloantibodies with differential reactivity for HLA proteins encoded by specific alleles within a serologic antigen group. Allele-specific antibodies are associated with positive cellular crossmatches not accurately predicted by standard donor HLA genotyping and can manifest as post-transplant donor-specific antibodies. Our data highlights the importance of evaluating anti-HLA antibodies at the allele-level and provides evidence supporting utility for high-resolution HLA genotyping in solid organ transplantation.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/métodos , Genótipo , Antígenos HLA/genética , Isoanticorpos/sangue , Transplante de Órgãos , Adulto , Alelos , Feminino , Histocompatibilidade , Humanos , Incidência , Masculino , Polimorfismo Genético , Análise de Sequência de DNA , Estados Unidos/epidemiologia
19.
Am J Clin Pathol ; 155(1): 117-123, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33049048

RESUMO

OBJECTIVES: RBC alloantibodies can lead to ABO grouping discrepancies unrelated to A or B antigens or antibodies posing challenges in the blood bank testing. Routine blood bank testing and flow cytometry were used to immunophenotype reagent cells and elucidate the cause of ABO discrepancies in two patients. METHODS: ABO discrepancy was identified in two patients after transfusion with several units of RBCs. For both patients, the pretransfusion type and screen demonstrated blood group A. Eight and 16 days later, both patients showed an apparent antibody to reagent group A cells, which prompted additional study with patients' samples and flow cytometric testing of commercial reagent cells. RESULTS: In both patients' specimens, posttransfusion evaluation demonstrated an emerging antibody to the Kell antigen (K). The RBCs of both patients typed negative for K, and both were transfused with K-positive RBCs. Flow cytometric analysis of reagent RBCs demonstrated that five of seven lot numbers were positive for K. CONCLUSIONS: Emerging anti-K antibody led to agglutination of the K-positive reagent A1 cells, highlighting the importance of considering RBC alloantibodies and the composition of reagent cells when interpreting cases with an apparent ABO grouping discrepancy.


Assuntos
Sistema ABO de Grupos Sanguíneos/imunologia , Tipagem e Reações Cruzadas Sanguíneas/métodos , Eritrócitos/imunologia , Isoanticorpos , Idoso , Transfusão de Sangue , Feminino , Citometria de Fluxo , Humanos , Masculino , Pessoa de Meia-Idade
20.
Transfus Apher Sci ; 60(1): 102970, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33223473

RESUMO

BACKGROUND: With more hospitals using low-titer group O whole blood in trauma resuscitation, having an efficient screening method for low-titer donors is critical. Our blood center uses an automated screen for high-titer isohemagglutinins in our platelet donations while collecting detailed donor demographic information. Using this data, we can identify key demographics often associated with titer status, thereby helping develop a donor-triaging method for titering. STUDY DESIGN AND METHODS: Titer results were read with an automated microplate system as either high or low, based on agglutination, with a cutoff equivalent to 1:256 (both anti-A and anti-B). Donor demographic data analyzed included date of donation, blood group, age, gender, and ethnicity. RESULTS: 57,508 donations were collected from 2073 unique donors between 2014 and 2018. We found the following demographics to be correlated with titer status: gender, ABO blood group, age, and ethnicity. Variability in titer status was identified in 215 individuals. This represented around 10 % of the total unique donors and was split equally amongst gender. We also found that donors between the ages of 41-60 ha d the highest likelihood of having variability in titer status, peaking at 13 %, and this proportion declined past age 60. CONCLUSION: Titer status is associated with the following donor demographics: gender, ABO type, age, and ethnicity. We also discovered that variability in titer status is correlated with age. In blood centers that do not have automated and routine titer screening procedure, these findings could be used as a method to efficiently identify low-titer donors a-priori.


Assuntos
Doadores de Sangue/estatística & dados numéricos , Tipagem e Reações Cruzadas Sanguíneas/métodos , Hemaglutininas/sangue , Programas de Rastreamento/métodos , Adulto , Idoso , Demografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...